null

Quattro 2.5 4 Channel Clinical Stim Unit

Roscoe Medical
SKU:
13-3370
$800.00
$749.00
UPC:
092237603086

A microprocessor controlled professional four-channel electrotherapy device, this device provides IF 4-Pole, IF 2-Pole, Russian, EMS and TENS waveforms with two separate timers. The Roscoe Medical Quattro 2.5 4-Channel Clinical Stim Unit features a portable design that lets you take it to your patient or keep it at the clinic. It’s easy to use and up and running within minutes. The Quattro 2.5 has an advanced operating system that ensures a complete range of therapy no matter where you use it. Includes eight sets of electrodes, eight sets of rubber electrodes with sponges, four elastic straps, four sets of lead wires, two connector cables, power cord and user manual with preset protocol guide.

FEATURES:

  • Two separate timers to treat two areas/patients at once or one larger area
  • STIM indicator light for precise intensity control
  • Four channels of electrical stimulation output
  • Large easy-to-read graphical LCD display with exact dial performance and programmable timer
  • Waveforms include TENS, EMS, 2-Pole Interferential, 4-Pole Interferential and Russian
  • 10 presets per waveform totaling 50 presets (plus professional mode)
  • Preset protocols as well as customized user defined protocols
  • Designed for tabletop, therapy cart or mobile use
  • Product dimensions: 10.5" (W) x 15" (L) x 8" (H)
  • Product weight: 6.7 lbs
  • Two year warranty

What's In the Box:

  • 8x Sets of Electrodes
  • 8x Sets of Rubber Electrodes with Sponges
  • 4x Elastic Straps
  • 4x Sets of Lead Wires
  • Two Connector Cables
  • Power Cord
  • User Manual with Preset Protocol Guide

Product Specifications:

  • Waveform:
    • Mono-phasic square (TENS)
    • Biphasic square (2-pole, 4-pole, EMS, & Russian)
  • Mode Selection: CC (Constant Current) or CV (Constant Voltage)
  • Adapter Supply Voltage: 100-240 VAC, 50-60 Hz, 0.6A
  • Adapter Output: 15V - 1.2A Max.
  • Maximum Treatment Time: 60 Minutes

Waveform Specifications:

  • 4-Pole Interferential Mode
    • Waveform Type: Bi-phasic square
    • Mode Selection: CC (Constant Current) or CV (Constant Voltage)
    • Vector: Auto: 0%-100%, Manual: 0°-90°
    • Carrier Frequency (C.F.): 4.0kHz
    • Sweep Low Beat Frequency (Beat L): 1 - (Beat H) Hz
    • Sweep High Beat Frequency (Beat H): (Beat L) - 150 Hz
    • Output Intensity: 0-50mA (CC, at 1k ohm load); 0-50V (CV, at 1k ohm load)
    • Treatment Time: 1-60 minutes
  • 2-Pole Interferential Mode
    • Waveform Type: Bi-phasic square
    • Mode Selection: CC (Constant Current) or CV (Constant Voltage)
    • Carrier Frequency (C.F.): 4.0kHz
    • Sweep Low Beat Frequency (Beat L): 1-(Beat H.) Hz
    • Sweep High Beat Frequency (Beat H): (Beat L.) - 150 Hz
    • Output Intensity: 0-50mA (CC, at 1k ohm load); 0-50V (CV, at 1k ohm load)
    • Treatment Time: 1-60 minutes
  • TENS Mode
    • Waveform Type: Mono-phasic square
    • Mode Selection: CC (Constant Current) or CV (Constant Voltage)
    • Frequency: 1-250 Hz
    • Frequency modulation (F.M.): 0-249 Hz
    • Burst Rate (Burst): 0-10Hz (7 pulse)
    • Phase Duration (P. Dur): 30-400µs
    • Amplitude Modulation (A.M.): 0%-100%
    • Output Intensity: 0-100mA (CC, at 1k ohm load); 0-100V (CV, at 1k ohm load)
    • Cycle Time (Cycle): Continuous, 4/4, 4/8, 7/7, 5/5, 4/12, 10/10, 10/20, 10/30, 10/50
    • Treatment Time: 1-60 minutes
  • EMS Mode
    • Waveform Type: Bi-phasic square
    • Mode Selection: CC (Constant Current) or CV (Constant Voltage)
    • Frequency: 1-250 Hz
    • Frequency Modulation (F.M.): 0-249 Hz
    • Step Duration (P. Dur): 30-400µs
    • Amplitude Modulation (A.M.): 0%-100%
    • Output Intensity: 0-100mA (CC, at 1k ohm load); 0-100V (CV, at 1k ohm load)
    • Treatment Time: 1-60 minutes
    • Ramp Time: 1s, 2s, and 5s
    • Cycle Time: Continuous, 4/4, 4/8, 7/7, 5/5, 4/12, 10/10, 10/20, 10/30, 10/50
  • Russian Mode
    • Waveform Type: Bi-phasic square
    • Mode Selection: CC (Constant Current) or CV (Constant Voltage)
    • Carrier Frequency (C.F.): 2.5kHz
    • Burst Frequency (Freq.): 20-100 Hz
    • Output Intensity: 0-50mA (CC, at 1k ohm load); 0-50V (CV, at 1k ohm load)
    • Duty Cycle: 10%, 20%, 30%, 40%, and 50%
    • Cycle Time: Continuous, 5/5, 4/12, 10/10, 10/20, 10/30, 10/50
    • Treatment Time: 1-60 minutes
    • Ramp Time (Ramp): 1s, 2s, and 5s

NOTE: CLASS II Device - Medical Professional license or Rx Required